{"id":1882,"date":"2012-01-30T10:38:24","date_gmt":"2012-01-30T10:38:24","guid":{"rendered":"http:\/\/www.camel-solar.com\/cs\/?page_id=1882"},"modified":"2021-01-18T15:34:49","modified_gmt":"2021-01-18T15:34:49","slug":"evacuated-tubes-15","status":"publish","type":"page","link":"http:\/\/www.camel-solar.com\/cs\/evacuated-tubes-15\/","title":{"rendered":"Evacuated Tubes 15"},"content":{"rendered":"<p style=\"text-align: center;\"><a title=\"Evacuated Tubes 10\" href=\"http:\/\/www.camel-solar.com\/cs\/evacuated-tubes-10\/\">Evacuated Tube 10<\/a>\u00a0|\u00a0<a title=\"Evacuated Tubes 15\" href=\"http:\/\/www.camel-solar.com\/cs\/evacuated-tubes-15\/\">Evacuated Tube 15<\/a>\u00a0|\u00a0<a title=\"Facade\" href=\"http:\/\/www.camel-solar.com\/cs\/facade\/\">Facade<\/a>\u00a0|\u00a0<a title=\"Flat Plate 2.0-2\" href=\"http:\/\/www.camel-solar.com\/cs\/flat-plate2-2\/\">Flat Plate 2.0-2<\/a>\u00a0|\u00a0<a title=\"Flat Plate 2.0-4\" href=\"http:\/\/www.camel-solar.com\/cs\/flat-plate-2-0-4\/\">Flat Plate 2.0-4<\/a><\/p>\n<div class=\"divider\"><\/div>\n<div class=\"col_13\">\n<p>This is Camel Solar\u2019s new Evacuated Tube Collector. The collector is composed of 15 evacuated tubes with highly efficient selective coatings. The Glass tube has a PVD (physical vapour deposition) selective coating inside enhancing the absorption of the tube.<\/p>\n<p>Inside the glass tube are U type copper pipes. These pipes are welded to an additional absorber. This absorber has its own patented selective coating increasing the heat transfer to the copper pipes and intern to the heat transfer fluid.<\/p>\n<p>The U type copper pipes join two separate manifolds which are carefully placed in an anodized aluminum box and insulated with a high density rock wall.<\/p>\n<p>Combining the latest research and technology this is one of the most efficient collectors on the market today and has recieved Solar Keymark Certification.<\/p>\n<p>The Collector is perfect for domestic, commercial and industrial applications with a stagnation temperature of 250\u00b0c. Clients are using these panels for swimming pool applications, heating pools past 30\u00b0c without any other form of energy.<\/p>\n<\/div>\n<div class=\"col_13\">\n<p><a href=\"http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2012\/01\/evac5.png\"><img loading=\"lazy\" class=\"alignleft  wp-image-3211\" title=\"evac5\" src=\"http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2012\/01\/evac5-592x1024.png\" alt=\"\" width=\"290\" height=\"502\" srcset=\"http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2012\/01\/evac5-592x1024.png 592w, http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2012\/01\/evac5-173x300.png 173w, http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2012\/01\/evac5-115x200.png 115w, http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2012\/01\/evac5.png 1398w\" sizes=\"(max-width: 290px) 100vw, 290px\" \/><\/a><\/p>\n<\/div>\n<div class=\"col_13 last\">\n<p>Contact us<\/p>\n<p>Phone<br \/>\n00 389 2 2602029<\/p>\n<p>Address<br \/>\nUl. Kacanicki Pat bb<br \/>\n1000 Skopje<br \/>\nRepublic of Macedonia<\/p>\n<p>Email<br \/>\nInfo@camel-solar.com<br \/>\nSales@camel-solar.com<br \/>\nMarketing@camel-solar.com<\/p>\n<p><a href=\"http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2012\/01\/Camel-Solar-Eva-15-GS.jpg\"><br \/>\n<\/a><a href=\"http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2013\/04\/Camel-Solar_brochure-1232013.pdf\"><br \/>\n<\/a><a href=\"http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2021\/01\/Catalog-Camel-Solar-brochure.pdf\"><img loading=\"lazy\" class=\"alignnone\" title=\"Camel Solar brochure link\" src=\"http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2012\/01\/Camel-Solar-brochure-link.jpg\" alt=\"\" width=\"166\" height=\"236\" \/><\/a><a href=\"http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2013\/01\/Eva-15-Spec.pdf\"><img loading=\"lazy\" title=\"Camel Solar Eva 15 GS\" src=\"http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2012\/01\/Camel-Solar-Eva-15-GS.jpg\" alt=\"\" width=\"166\" height=\"236\" \/><\/a><a href=\"http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2012\/01\/Camel-Solar-Eva-15-GS.jpg\"><br \/>\n<\/a><a href=\"http:\/\/www.camel-solar.com\/cs\/key-mark-email\/\"><img loading=\"lazy\" title=\"Camel Solar eva 15 SKD\" src=\"http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2012\/01\/Camel-Solar-eva-15-SKD.jpg\" alt=\"\" width=\"166\" height=\"236\" \/><\/a><\/p>\n<\/div>\n<div class=\"col_13\">\n<p><strong>Efficiency Curve<\/strong><\/p>\n<p><a href=\"http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2012\/01\/eta1016_1017.jpg\"><img loading=\"lazy\" title=\"eta1016_1017.xlsx\" src=\"http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2012\/01\/eta1016_1017-300x190.jpg\" alt=\"\" width=\"300\" height=\"190\" \/><\/a><\/p>\n<\/div>\n<div class=\"col_13 last\">\n<p><a href=\"http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2012\/01\/evacuated-tube-cross-section.png\"><img loading=\"lazy\" title=\"evacuated tube cross section\" src=\"http:\/\/www.camel-solar.com\/cs\/wp-content\/uploads\/2012\/01\/evacuated-tube-cross-section-1024x747.png\" alt=\"\" width=\"283\" height=\"206\" \/><\/a><\/p>\n<p style=\"text-align: left;\">1 | Aluminium Manifold \u00a0\u00a02 | Rubber Seal\u00a0\u00a03 | Thermal Sidewall Insulation \u00a04 | Absorber\u00a0\u00a05 | Glass Tube Double Wall Vacuum \u00a06 | Hot Supply Manifold\u00a0\u00a07 | Cold return Manifold<\/p>\n<\/div>\n<div><\/div>\n","protected":false},"excerpt":{"rendered":"Evacuated Tube 10\u00a0|\u00a0Evacuated Tube 15\u00a0|\u00a0Facade\u00a0|\u00a0Flat Plate 2.0-2\u00a0|\u00a0Flat Plate 2.0-4","protected":false},"author":1,"featured_media":1687,"parent":0,"menu_order":0,"comment_status":"open","ping_status":"open","template":"fullwidth.php","meta":[],"_links":{"self":[{"href":"http:\/\/www.camel-solar.com\/cs\/wp-json\/wp\/v2\/pages\/1882"}],"collection":[{"href":"http:\/\/www.camel-solar.com\/cs\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.camel-solar.com\/cs\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.camel-solar.com\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.camel-solar.com\/cs\/wp-json\/wp\/v2\/comments?post=1882"}],"version-history":[{"count":52,"href":"http:\/\/www.camel-solar.com\/cs\/wp-json\/wp\/v2\/pages\/1882\/revisions"}],"predecessor-version":[{"id":3716,"href":"http:\/\/www.camel-solar.com\/cs\/wp-json\/wp\/v2\/pages\/1882\/revisions\/3716"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.camel-solar.com\/cs\/wp-json\/wp\/v2\/media\/1687"}],"wp:attachment":[{"href":"http:\/\/www.camel-solar.com\/cs\/wp-json\/wp\/v2\/media?parent=1882"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}